{"id":840,"date":"2016-06-13T10:46:13","date_gmt":"2016-06-13T10:46:13","guid":{"rendered":"http:\/\/oilfiltration.globecore.com\/?page_id=840"},"modified":"2020-04-14T10:02:13","modified_gmt":"2020-04-14T10:02:13","slug":"oil-filtration-plant-cfu-1-7","status":"publish","type":"page","link":"https:\/\/oilfiltration.globecore.com\/oil-filtration-systems\/oil-filtration-plant\/oil-filtration-plant-cfu-1-7\/","title":{"rendered":"Oil Filtration Plant CFU-1.7"},"content":{"rendered":"<p style=\"text-align: center;\">\n<p>Oil Filtration Plant CFU is designed for removal of mechanical contaminations from transformer and lubricating oils.<\/p>\n<p><strong>Identification Key: C <\/strong>\u2013 cart, <strong>P<\/strong> \u2013 pump, <strong>SW<\/strong> \u2013 switch, <strong>F1<\/strong>\u2013 filter 1, <strong>F2<\/strong> \u2013 filter 2<\/p>\n<h2 style=\"text-align: center;\"><strong>DESCRIPTION<\/strong><\/h2>\n<p>Oil Filtration Plant CFU is a portable filtration unit, mounted on a cart. CFU consists of two filter housings with filter cartridges (filtration rate &#8211; 5 micron) and magnets, oil pump, switch and manometers.<\/p>\n<p>Oil is drown from external tank by pump P, through inlet Valve V1 and\u00a0 filters F1 and F2 back into external tank.<\/p>\n<h2 style=\"text-align: center;\"><strong>FLOW DIAGRAM<\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-853\" src=\"http:\/\/oilfiltration.globecore.com\/wp-content\/uploads\/sites\/23\/2016\/06\/flow-diagram.jpg\" alt=\"flow-diagram\" width=\"764\" height=\"266\" srcset=\"https:\/\/oilfiltration.globecore.com\/wp-content\/uploads\/sites\/23\/2016\/06\/flow-diagram.jpg 764w, https:\/\/oilfiltration.globecore.com\/wp-content\/uploads\/sites\/23\/2016\/06\/flow-diagram-600x209.jpg 600w\" sizes=\"auto, (max-width: 764px) 100vw, 764px\" \/><\/p>\n<p><strong>Identification Key: MF<\/strong> \u2013mesh filter, <strong>V1-V5<\/strong> \u2013 valves, <strong>M1, M2<\/strong> \u2013 manometers, <strong>F1, F2<\/strong> \u2013 filters, <strong>P<\/strong>&#8211; pump,<strong> SV<\/strong> \u2013 safety valve<\/p>\n<h2 style=\"text-align: center;\"><strong>SPECIFICATIONS<\/strong><\/h2>\n<table width=\"96%\">\n<tbody>\n<tr>\n<td width=\"5%\"><strong>\u2116<\/strong><\/td>\n<td width=\"82%\">\n<p style=\"text-align: center;\"><strong>Parameter<\/strong><\/p>\n<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\"><strong>Value<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">1<\/td>\n<td width=\"82%\">Production capacity max, m3\/h<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">1,7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">2<\/td>\n<td width=\"82%\">Filtration rate, micron<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">3<\/td>\n<td width=\"82%\">Power consumption, kW<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">1,5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">4<\/td>\n<td width=\"82%\">Pressure differential, MPa<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">0,4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">5<\/td>\n<td width=\"82%\">Oil pressure on outlet, MPa<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">0,25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">8<\/td>\n<td width=\"82%\">Power supply, 60 Hz, V, 3 Ph.<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">480<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">9<\/td>\n<td width=\"82%\">Dimensions, mm<\/p>\n<p>&#8211; length<\/p>\n<p>&#8211; width<\/p>\n<p>&#8211; height<\/td>\n<td width=\"12%\">&nbsp;<\/p>\n<p style=\"text-align: center;\">600<\/p>\n<p style=\"text-align: center;\">600<\/p>\n<p style=\"text-align: center;\">1100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"5%\">10<\/td>\n<td width=\"82%\">Weight, kg<\/td>\n<td width=\"12%\">\n<p style=\"text-align: center;\">60<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Oil Filtration Plant CFU is designed for removal of mechanical contaminations from transformer and lubricating oils. Identification Key: C \u2013 cart, P \u2013 pump, SW \u2013 switch, F1\u2013 filter 1, F2 \u2013 filter 2 DESCRIPTION Oil Filtration Plant CFU is a portable filtration unit, mounted on a cart. CFU consists of two filter housings with<a class=\"cg-read-more\" href=\"https:\/\/oilfiltration.globecore.com\/oil-filtration-systems\/oil-filtration-plant\/oil-filtration-plant-cfu-1-7\/\" target=\"_blank\">Read More <\/a><\/p>\n","protected":false},"author":7,"featured_media":4697,"parent":120,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-single-products.php","meta":{"footnotes":""},"class_list":["post-840","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"language":"en","_links":{"self":[{"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/comments?post=840"}],"version-history":[{"count":0,"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/840\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/pages\/120"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/media\/4697"}],"wp:attachment":[{"href":"https:\/\/oilfiltration.globecore.com\/en\/wp-json\/wp\/v2\/media?parent=840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}